$1,405.40
-
$7,234.19
-
$105.95
-
$75.35
-
$77.77
-
$20.37
-
$276.72
-
$342.71
-
$88.82
-
$148.62
Memphis Control Center stocks Laars Heating Systems OEM replacement parts for Mighty Therm, NeoTherm, Pennant, Mascot, Rheos, JVH, and DVi series boilers and water heaters. Top-searched parts in stock: pilot assemblies (R20607400), aquastats (RE0093200 / L6008G1009, 130-230°F, 66" capillary), gas valves (R0099400 3/4" 24V natural gas), ignition modules (2400-224, RE0253400), pressure switches, temperature controls, gaskets, sight tiles, fuses, and hardware. Also known as Teledyne Laars. Laars is a subsidiary of Bradford White Corporation and manufactures residential and commercial heating products from 50,000 to 5,000,000 BTU/hr in Rochester, New Hampshire. Family-owned, serving Memphis since 1967.
The Laars parts most frequently searched and ordered online - pilot assemblies, aquastats, ignition modules, gas valves, and controls for Mighty Therm, NeoTherm, Pennant, Rheos, and legacy Teledyne Laars series. Contact us or call (901) 458-2000 with your Laars part number or boiler model and serial number.
Laars pilot assemblies are among the most frequently ordered replacement parts for Laars and Teledyne Laars boilers and water heaters. The pilot assembly provides the standing pilot or spark ignition pilot flame that lights the main burner. When a pilot assembly fails, the boiler will not fire. The R20607400 is the most widely searched Laars pilot assembly - a pilot assembly with burner for Teledyne Laars heating systems, stocked at Memphis Control Center. Always confirm your boiler model number and serial number when ordering a pilot assembly, as different Laars series use different pilot assemblies.
| Part Number | Description | Shop |
|---|---|---|
| R20607400 | Pilot assembly with burner for Laars heating systems | Shop |
Additional Laars pilot assembly part numbers frequently ordered: R10526400, R10529300 (Honeywell System 9 NG), R20039600, R20094900, RW2001800 (hot surface ignition NG), R0096000 (NG pilot burner), R0096700 (NG pilot assembly), W0034400 (standing pilot LP). Call (901) 458-2000 to confirm which pilot assembly your specific Laars model requires.
The RE0093200 (Honeywell equivalent L6008G1009) is the most widely searched Laars aquastat. It is a two-stage operating control and thermostat for Laars hydronic boilers, with a temperature range of 130-230°F and a 66" capillary. It controls boiler water temperature for proper operation and prevents overheating. Used in residential and commercial hydronic heating systems. The RE0066200 is a dual aquastat with manual reset, 100-240°F range, and 144" capillary for larger Laars boiler installations. Memphis Control Center stocks RE0093200.
| Part Number | Description | Shop |
|---|---|---|
| RE0093200 | 130-230°F aquastat · 66" capillary · L6008G1009 · 2-stage operating control | Shop |
| RE0066200 | Dual aquastat · 100-240°F · manual reset · 144" capillary | Shop |
Additional Laars temperature controls frequently ordered: RE2344300 (PCB temp control module), RE0096200 (thermostat 2-stage 130-230°F), RE0014400 (high limit auto reset), E0015900 (high limit manual reset), E2106800 (temperature control 4-stage). Call (901) 458-2000 to confirm part number for your Laars model.
Laars ignition modules control the ignition sequence on Laars gas boilers and water heaters. The 2400-224 is a 24V ignition module (also listed as a diagnostic control board for the 2400 series) - one of the most frequently searched Laars parts online and stocked at Memphis Control Center. The RE0253400 is a 24V ignition module with 15-second prepurge and 7-second trial for ignition (15sPP 7sTFI). The RE0100900 is an ignition control kit for electronic NG ignition, G67AG-3 (replaces E0075900, E0100900, used on Mighty Therm 500K BTU and up).
| Part Number | Description | Shop |
|---|---|---|
| 2400-224 | 24V ignition module · 2400 series diagnostic control board | Shop |
Additional Laars ignition controls frequently ordered: RE0253400 (24V ignition module, 15sPP 7sTFI), RE0100900 (G67AG-3 ignition kit, Mighty Therm 500K+), R0011900 (ignition control NG continuous try), R0097100 (ignition control spark 1-try), E2105100 (ignition control 3-try), R2023000 (Fenwal ignition control), RE0100900 (kit G67). Call (901) 458-2000 with your boiler serial number to confirm the correct ignition module.
Laars gas valves, pressure switches, flow switches, and miscellaneous replacement components for Laars boilers and water heaters. The R0099400 is a 3/4" 24V natural gas valve (0.2" W.C.) stocked at Memphis Control Center. The RE2218701 is a water pressure switch. The RE0240900 is a differential pressure switch at 0.75" W.C. for Pennant 500-2000 series. Memphis Control Center also stocks boiler tiles (T2015600, right tile with sight hole), fuses (E2318700, 6.25A 250V, size 3AG), and hardware (24B2001, top/bottom retainer bolt).
| Part Number | Description | Shop |
|---|---|---|
| R0099400 | 3/4" · 24V · natural gas valve · 0.2" W.C. inlet pressure | Shop |
| RE2218701 | Water pressure switch | Shop |
| T2015600 | Tile, right with sight hole | Shop |
| E2318700 | Fuse · 6.25A · 250V · size 3AG | Shop |
| 24B2001 | Top/bottom retainer bolt | Shop |
Additional Laars parts frequently ordered: RE0240900 (differential pressure switch 0.75" W.C., Pennant 500-2000), RE2058300 (nickel-plated immersion well), RE2074400 (transformer), E2318700 (fuse 6.25A), RA0079000 (temperature and pressure gauge 70-250°F / 0-225 PSI), R2004000 (high gas pressure switch), R2004100 (low gas pressure switch), E0013100 (flow switch indoor), E2075900 (low water cutoff), S0024600 (pump housing gasket), S0095100 (header gasket).
Laars manufactures heating products across residential and commercial markets from 50,000 to 5,000,000 BTU/hr. When ordering replacement parts, always have your boiler model number and serial number ready. Call (901) 458-2000 and we will confirm the correct part for your specific series and vintage.
| Series | Type | Application | Key Notes |
|---|---|---|---|
| Residential Boilers | |||
| Mascot FT (MFTHW / MFTCW) | Condensing fire-tube boiler / combi | Residential heating and domestic hot water | 95% AFUE, AHRI certified, modulating, 81K-157K BTU, NG or LP |
| Mascot LX | Condensing modulating combi boiler | Residential heating and DHW | 95% AFUE, zero-clearance, up to 150 ft venting, NG or LP, 10 models |
| Commercial Boilers | |||
| NeoTherm | Modulating condensing boiler | Commercial hydronic heating | 95% AHRI efficiency, ASME stainless steel heat exchanger, NOx below 10 ppm |
| NeoTherm XTR | Modulating condensing boiler | Commercial, extended range | AHRI-certified 96%+ thermal efficiency, 10:1 combustion turndown, extended capacity range |
| Mighty Therm 2 (MT2) | Cast iron commercial boiler | Commercial heating, process | Legacy workhorse series; parts R0099400, RE0100900, RE0093200 most ordered |
| Pennant | Commercial boiler / water heater | Commercial heating and hot water | RE0240900 differential pressure switch 0.75" W.C. is common Pennant part |
| Commercial Water Heaters | |||
| JVH | Volume water heater | Commercial domestic hot water | High-capacity commercial water heating; R0394918 flue outlet JVH 160 stocked |
| Magnatherm FT | Commercial condensing water heater | Large commercial and institutional | Up to 2,000 MBH; used on college campuses, hotels, hospitals |
| Pool Heaters | |||
| Rheos | Commercial pool heater | Commercial pool and spa heating | Legacy of original 1948 Laars pool heater design; blower part R2012100 for Rheos |
Common questions from HVAC technicians, plumbers, boiler service companies, and facility managers about Laars (Teledyne Laars) OEM replacement parts. Contact us or call (901) 458-2000 with your model and serial number.
What is the difference between Laars and Teledyne Laars?
They are the same company at different points in its history. Laars was founded in 1948 in California. During a period of corporate ownership, the company was part of Teledyne Corporation and products were marketed as Teledyne Laars - that name still appears on millions of installed boilers and water heaters, and parts are listed under both names online. The company is now a subsidiary of Bradford White Corporation, headquartered in Rochester, New Hampshire. When searching for parts, either name leads to the same OEM parts.
What is the Laars RE0093200 aquastat (L6008G1009)?
The RE0093200 is a two-stage operating control and thermostat (aquastat) for Laars hydronic boilers. It uses a Honeywell L6008G1009 sensing element, has a temperature range of 130 to 230°F, and a 66-inch capillary. It controls boiler water temperature for proper operation and prevents overheating. It is one of the most widely ordered Laars replacement parts, used across multiple Laars series. Memphis Control Center stocks the RE0093200 - call (901) 458-2000 to confirm availability.
What does the Laars 2400-224 ignition module do?
The 2400-224 is a 24V ignition module (also described as a diagnostic control board) for Laars 2400 series boilers and water heaters. It controls the gas ignition sequence. When it fails, the unit will not attempt ignition. It is one of the most searched Laars parts online. Memphis Control Center stocks the 2400-224. Always confirm your boiler model and serial number when ordering an ignition module, as different Laars series use different ignition controls.
How do I find the correct replacement part for my Laars boiler?
Locate the model number and serial number on your boiler nameplate - typically on the front or side of the unit. Call Memphis Control Center at (901) 458-2000 with that information and we will identify the correct OEM part. Many Laars parts changed numbers over production runs (for example, E0093200 updated to RE0093200, E0100900 updated to RE0100900) - the serial number helps confirm which version applies to your unit.
What Laars series does Memphis Control Center stock parts for?
Memphis Control Center stocks Laars OEM parts for Mighty Therm (MT2 and legacy), NeoTherm, NeoTherm XTR, Pennant, Mascot FT, Mascot LX, Rheos pool heaters, JVH volume water heaters, Magnatherm FT, DVi, and legacy Teledyne Laars boilers and water heaters across the full production history. Laars covers 50,000 to 5,000,000 BTU/hr in natural gas, LP, and electric. Call (901) 458-2000 with your model and serial number for any Laars part.
Is Laars still in business and who owns them now?
Yes. Laars Heating Systems is active and manufacturing from its Rochester, New Hampshire facility, where every unit is live-fired before shipping. Laars is currently a subsidiary of Bradford White Corporation. The brand was founded in 1948 in California by engineer Avy Miller, was part of Teledyne Corporation (Teledyne Laars name), became part of Waterpik Technologies in 1999, and is now under Bradford White. Parts and service support for all Laars series remain available.
Call us with your part number or your boiler model and serial number. Same-day shipping on stocked parts from Memphis, TN. We cover Mighty Therm, NeoTherm, Pennant, Mascot, Rheos, JVH, and all legacy Teledyne Laars series.
For emergencies, outside of business hours, call #901-604-7069