700+ Pressure Switches In Stock — Ships Today from Memphis, TN

Pressure Switches — Air Differential, Gas Pressure
& Combustion Air Proving Switches

Shop 700+ pressure switches for commercial boilers, burners, and HVAC equipment including Antunes JD-2 air differential switches, HLGP and RHGP gas pressure switches, Honeywell C6097 combustion air pressure switches, and Cleveland Controls air proving switches. Free same-day shipping from Memphis, TN since 1967.

Stocking distributor: Antunes Honeywell Cleveland Controls
700+ Switches In Stock Antunes · Honeywell · Cleveland Controls Free Same-Day Shipping In Business Since 1967
Safety-Critical StockGas and combustion air pressure switches required by code on commercial boilers and burners
700+ ModelsAir differential, gas pressure, and combustion air proving switches in stock
Minimize DowntimeIn-stock switches ship same day — no waiting when a boiler trips offline
Same-Day ShippingOrders by 2 PM CT ship same day — always free

Pressure Switch Brands We Stock

We stock pressure switches from three brands covering every application in commercial boiler, burner, and HVAC service. Find your brand below or call our team for selection help.

Antunes
JD-2 Air Differential, HLGP & RHGP Gas Pressure Switches — 312 Products

Antunes is our largest pressure switch line with 312 products across two major families:

JD-2 Air Differential Pressure Switches — the most widely used air differential pressure switch in commercial boiler and burner applications. Color-coded by pressure range for easy identification: Red, Orange, Purple, Yellow, Blue, Green, and other variants covering 0.1" to 10" W.C. Available in SPDT and DPDT configurations with 1/8" NPT or Harrison connector ports. Auto-reset and manual-reset versions.

HLGP / RHGP Gas Pressure Switches — high/low gas pressure safety switches for commercial boilers and burners. The HLGP-A has two SPDT contacts (2-SPDT) combining high and low gas pressure proving in one unit with 3/8" NPT high pressure and 1/8" NPT low pressure connections. The HLGP-D is the dual-range version with extended setpoint ranges. Manual reset (HLGP) and auto reset (RHLGP/RHGP) available. Required by ASME CSD-1 and NFPA 85 on commercial boilers.

JD-2 Air DifferentialHLGP-A High/Low GasHLGP-D Extended RangeRHLGP Auto ResetRHGP High GasHGP / LGP Series
Honeywell
C6097 Combustion Air Pressure Switches — 28 Products

Honeywell C6097 combustion air pressure switches are used on commercial and industrial boilers and burners to prove combustion air flow before and during burner operation. Available in break-on-rise (C6097B) and break-on-fall (C6097A) configurations with auto-reset and manual-reset options. Pressure ranges from 0.4" to 200" W.C. All models feature 1/4" NPT connection.

The C6097 is required by ASME CSD-1 on commercial boilers as a combustion air proving switch — it verifies that combustion air is flowing before allowing the burner to fire, preventing unsafe operation with insufficient air.

C6097A Break-on-FallC6097B Break-on-RiseAuto & Manual Reset0.4"–200" W.C.1/4" NPT
Cleveland Controls
Air Flow Switches & Air Proving Switches — 366 Products

Cleveland Controls manufactures air flow switches, air pressure switches, and air proving switches for commercial HVAC, boiler, and industrial applications. Their product line covers the FS-751 air flow switch series, NS2 adjustable pressure switch series, AFS air flow switch series, and DDP/DFS differential pressure switch series — commonly used for proving combustion air, duct air flow, and fan operation in boiler rooms and HVAC equipment.

Note: Many Cleveland Controls items in our catalog are special-order or low-stock. Contact us to confirm availability before ordering on specific Cleveland Controls part numbers.

FS-751 Air Flow SwitchNS2 Pressure SwitchAFS Air Flow SwitchDDP DifferentialAir ProvingDFSL / DFSH Fixed Set

Antunes JD-2 Color Code Guide

Antunes JD-2 air differential pressure switches are color-coded by pressure range — the color identifies which switch you need without measuring. Common color codes and their pressure ranges:

ColorPressure RangePart NumberReset Type
Red (JD-2R)0.1–24" W.C.801111303Auto Reset, SPDT
Orange (JD-2O)0.1–4.0" W.C.801111315Auto Reset, SPDT
Purple (JD-2P)0.1–10.0" W.C.801111310Auto Reset, SPDT
Grey (JD-2G)0.1–4.0" W.C.801111302Auto Reset, SPDT
Blue (JD-2B)0.07–1.7" W.C.801111301Auto Reset, SPDT
Black (JD-2)Adjustable, see product801111318Auto Reset, SPDT

Note: The Antunes JD-2 product line is now manufactured by Crossroads Controls (acquired from Antunes in 2017) but continues to be sold under the Antunes/JD-2 name. Not sure which color you need? Contact us or call (901) 458-2000.

Types of Pressure Switches We Stock

Air Differential Pressure Switches

Prove combustion air flow, fan operation, or duct air pressure. Antunes JD-2 color-coded series (0.1"–10" W.C.) and Cleveland Controls FS-751 and NS2 series for boilers and HVAC.

Gas Pressure Switches

High and low gas pressure safety switches required by ASME CSD-1 and NFPA 85 on commercial boilers. Antunes HLGP-A (2-SPDT, manual reset), RHLGP (auto reset), and RHGP (high gas only) series with high/low gas pressure proving in one unit.

Combustion Air Proving Switches

Verify combustion air is flowing before and during burner operation. Honeywell C6097A (break-on-fall) and C6097B (break-on-rise) in pressure ranges from 0.4" to 200" W.C., 1/4" NPT.

Manual Reset vs. Auto Reset

Manual reset switches require operator action after a trip event — preferred where the cause must be investigated before restart. Auto reset switches restore automatically when pressure returns to normal range.

SPDT Switches

Single Pole Double Throw — the standard configuration for most JD-2, C6097, and HLGP pressure switches. Provides one normally-open and one normally-closed contact for flexible circuit control in boiler management applications.

Break-on-Rise vs. Break-on-Fall

Break-on-rise (C6097B) opens the circuit when pressure rises above setpoint. Break-on-fall (C6097A) opens when pressure falls below setpoint. Selection depends on whether the switch proves presence or absence of pressure/flow.

Need help selecting the right pressure switch? Air differential, gas pressure, or combustion air proving — we specify these daily. Orders by 2 PM CT ship same day — free.

Precision and Reliability with Our Pressure Switches

 

Compare
Show 12 24 36 48 96

Need help selecting the right pressure switch?

Air differential, gas pressure, or combustion air proving — we specify these for commercial boilers and burners daily.

Pressure Switches — Frequently Asked Questions

Common questions about air differential, gas pressure, and combustion air proving switches. Contact our team or call (901) 458-2000 for selection help.

What is the Antunes JD-2 pressure switch used for?

The Antunes JD-2 is an air differential pressure switch widely used on commercial boilers and burners to prove combustion air flow. It senses the pressure difference across a combustion air blower — if the differential drops below the setpoint, it opens the circuit and shuts down the burner. JD-2 switches are color-coded by pressure range: Red/JD-2R (0.1–24" W.C.), Orange/JD-2O (0.1–4.0" W.C.), Purple/JD-2P (0.1–10.0" W.C.), Grey/JD-2G (0.1–4.0" W.C.), Blue/JD-2B (0.07–1.7" W.C.). All standard models are auto-reset SPDT with 1/8" NPT connections. Note: the Antunes JD-2 line is now manufactured by Crossroads Controls (acquired 2017) but sold under the same part numbers.

What is the difference between the Antunes HLGP-A and HLGP-D?

Both Antunes HLGP switches provide combined high and low gas pressure safety monitoring. The HLGP-A has two SPDT contacts (2-SPDT) — it combines high and low gas pressure proving in one unit with separate 3/8" NPT high pressure and 1/8" NPT low pressure connections. The HLGP-D provides extended setpoint ranges for different pressure applications. Manual-reset (HLGP) requires operator action after a trip; auto-reset (RHLGP) restores automatically when pressure returns to range.

What is the difference between the Honeywell C6097A and C6097B?

Both are Honeywell C6097 combustion air pressure switches but they trip in opposite directions. C6097A breaks on pressure fall — opens the circuit when pressure drops below setpoint, used to prove air flow is present. C6097B breaks on pressure rise — opens when pressure rises above setpoint, used where the switch must open on high pressure. Both available in auto-reset and manual-reset, pressure ranges 0.4" to 200" W.C., 1/4" NPT connection.

Why do commercial boilers require gas pressure switches?

ASME CSD-1 and NFPA 85 require gas pressure switches on commercial boilers to verify that gas pressure is within the acceptable operating range. A high gas pressure switch prevents firing if gas pressure is too high; a low gas pressure switch prevents firing if pressure is too low — either condition could result in an unsafe combustion event. Antunes HLGP and RHLGP switches combine both functions in a single unit, simplifying installation and wiring.

What is an air proving switch?

An air proving switch verifies that combustion air flow is established before allowing a burner or boiler to fire. It senses the pressure differential across the combustion air blower to confirm air movement — if the fan fails or loses capacity, the pressure drops and the switch prevents ignition or shuts down the burner. Honeywell C6097, Antunes JD-2, and Cleveland Controls FS-751 and NS2 switches are all commonly used as air proving switches on commercial boilers.

Related Categories

Commonly ordered alongside pressure switches.

For emergencies, outside of business hours, call #901-604-7069