Antunes Pressure Switches — Stocking Distributor · Memphis, TN

Antunes Pressure Switches —
JD-2 Air Differential & Model A Gas Pressure Switches

Memphis Control Center stocks Antunes JD-2 color-coded air differential pressure switches and Model A gas pressure switches (HLGP-A, RHLGP-A, HGP-A, LGP-A) for commercial boilers, burners, and HVAC equipment. The JD-2 series is the industry standard for air proving and combustion air flow verification on commercial boilers. The JD-2 color identifies the pressure range — no measuring required. Free same-day shipping from Memphis, TN since 1967.

Antunes Stocking Distributor JD-2 Air Differential · Model A Gas Pressure 312 Products Free Same-Day Shipping
UL · FM · CSA ListedJD-2 approved by Underwriters Laboratories, Factory Mutual, and Canadian Standards Association
ASME CSD-1 & NFPA 85Gas and combustion air pressure switches required by code on commercial boilers and burners
Color-Coded SelectionJD-2 spring color identifies the pressure range — 5 colors covering 0.07" to 35" W.C.
Same-Day ShippingOrders by 2 PM CT ship same day — always free

JD-2 Series — Select by Color

The Antunes JD-2 is a diaphragm-type, SPDT snap-action air differential pressure switch in a rugged die-cast aluminum housing with a visible on/off indicator. The spring color identifies the adjustable pressure range — choose the color that covers your required setpoint. All standard JD-2 models are auto reset, SPDT rated at 10A · 1/8 HP · 125 VAC / 5A · 1/4 HP · 250 VAC · Pilot Duty 125 VA, 1/8" NPT connections, rated -20°F to 140°F, max 35" W.C. operating pressure, max surge 3 PSIG. UL Listed (File MH8009-504), FM Approved (Serial 18221), CSA Certified (File 25144). Now manufactured by Crossroads Controls (acquired from Antunes in 2017) — same part numbers, same switches.

JD-2 Blue
0.07" – 1.7" W.C. 801111301 · JD-2B
JD-2 Grey
0.1" – 4.0" W.C. 801111302 · JD-2G
JD-2 Purple
0.1" – 10.0" W.C. 801111310 · JD-2P
JD-2 Red
0.1" – 24.0" W.C. 801111303 · JD-2R
JD-2 Orange
5.0" – 35.0" W.C. 801111315 · JD-2O
JD-2 Adjustable
Field Adjustable 801111318 — Contact Us

Note: The JD-2 product line is now manufactured by Crossroads Controls, which acquired Antunes Controls in 2017. Part numbers, specifications, and dimensions are unchanged — the switches are identical to the original Antunes JD-2 series.

Model A Gas Pressure Switches — HLGP-A & Single-Function Series

The Antunes Model A series monitors gas supply pressure on commercial boilers and burners as required by ASME CSD-1 and NFPA 85. Available in high/low combination, high-only, and low-only versions, in both manual reset and auto reset. Contact us for the right model and pressure range for your application.

High/Low Gas · Manual Reset HLGP-A

Antunes HLGP-A — High/Low Gas Pressure Switch, Manual Reset. Monitors both high and low gas supply pressure in a single unit — trips and requires manual reset if pressure goes above the high setpoint or below the low setpoint. 2-SPDT contacts. Adjustable pressure ranges: High 5–28" W.C. (3/8" NPT) and Low 1–6" W.C. (1/8" NPT), with additional range options available. Required by ASME CSD-1 for proving gas pressure within acceptable limits before and during burner operation.

High + Low Gas Pressure Manual Reset 2-SPDT 3/8" NPT High · 1/8" NPT Low Multiple Ranges Available
High/Low Gas · Auto Reset RHLGP-A

Antunes RHLGP-A — High/Low Gas Pressure Switch, Auto Reset. Same function as the HLGP-A but with automatic reset — the switch automatically resets when pressure returns to within the acceptable range, without requiring manual intervention. 2-SPDT contacts. Available in pressure ranges: High 2–16" / Low 1–6" W.C. (804112101), High 5–28" / Low 1–6" W.C. (804112102), High 10–50" / Low 1–6" W.C. (804112103), and additional range combinations.

High + Low Gas Pressure Auto Reset 2-SPDT Multiple Ranges Available
Single Function HGP-A & LGP-A

Antunes HGP-A (High Gas Pressure, Manual Reset) — monitors high gas pressure only. Trips and requires manual reset if pressure exceeds the high setpoint. Antunes LGP-A (Low Gas Pressure, Manual Reset) — monitors low gas pressure only. Trips and requires manual reset if pressure falls below the low setpoint. Both available with auto reset variants: RHGP (high gas auto reset) and RLGP-A (low gas auto reset).

HGP-A — High Only LGP-A — Low Only Manual Reset Auto Reset Variants Available
Sensitive Air Switches SML & SMD

Antunes SML (Sensitive Magnehelic-Level) — very low pressure sensing switch for applications requiring detection of extremely small pressure differentials, including draft sensing and air proving on low-resistance burner systems. Antunes SMD (Sensitive Magnehelic Differential) — sensitive differential pressure switch for monitoring pressure differences across filters, heat exchangers, or other components. Both are designed for applications where standard JD-2 sensitivity is insufficient.

Very Low Pressure Sensing SML — Single Port SMD — Differential Draft Sensing
Antunes

Antunes

Compare

Not sure which JD-2 color or gas pressure switch you need?

Tell us your boiler or burner make, model, and required setpoint — we'll identify the right switch.

Antunes Pressure Switches — Frequently Asked Questions

Common questions about the Antunes JD-2 and Model A gas pressure switches. Contact our team or call (901) 458-2000 for selection help.

How do I choose the right JD-2 color?

The JD-2 spring color identifies the adjustable pressure range — choose the color whose range includes your required setpoint: Blue (0.07–1.7" W.C.) for very low pressure; Grey (0.1–4.0" W.C.) for low-range air proving; Purple (0.1–10.0" W.C.) for mid-range; Red (0.1–24.0" W.C.) for wide-range; Orange (5.0–35.0" W.C.) for higher pressure ranges. Not sure of your required setpoint? Call us at (901) 458-2000 with your boiler or burner make and model.

What is the JD-2 used for on a commercial boiler?

The Antunes JD-2 is an air differential pressure switch used to prove combustion air flow — a function called air proving. It senses the pressure differential created by the combustion air blower to confirm air is moving before allowing the burner to fire. If the fan fails or loses capacity, the pressure drops and the JD-2 opens its contacts to prevent ignition or shut down the burner. Air proving switches are required by ASME CSD-1 and NFPA 85 on commercial boilers. The JD-2 can also be used for duct air pressure, vacuum, and differential pressure applications.

What is the difference between the HLGP-A and RHLGP-A?

Both monitor high and low gas pressure in a single unit with 2-SPDT contacts. The difference is the reset mechanism: the HLGP-A requires manual reset — an operator must physically press the reset button after a trip. The RHLGP-A has automatic reset — it resets when gas pressure returns to within the acceptable range. ASME CSD-1 requires manual reset gas pressure switches on boilers above certain input ratings — check your local code requirements to confirm which your application requires.

Is the JD-2 still made by Antunes?

The JD-2 air pressure switch is now manufactured by Crossroads Controls, which acquired the JD-2 product line from Antunes Controls in 2017. Part numbers, specifications, dimensions, and performance are unchanged — the switches are functionally identical to the original Antunes JD-2. They continue to be sold under the Antunes/JD-2 name.

What are the JD-2 operating specifications?

All standard JD-2 models share these specifications: SPDT snap-action rated at 10A · 1/8 HP · 125 VAC / 5A · 1/4 HP · 250 VAC / Pilot Duty 125 VA @ 125–250 VAC · 1/8" NPT port connections · Auto reset · Rugged die-cast aluminum housing with visible on/off indicator and setpoint indication · Max operating pressure 35" W.C. · Max pressure surge 3 PSIG · Ambient temperature -20°F to 140°F · UL Listed (File MH8009-504) · FM Approved (Serial 18221) · CSA Certified (File 25144). The spring color determines the adjustable setpoint range.

For emergencies, outside of business hours, call #901-604-7069