Allanson Transformers — Authorized Stocking Distributor · Memphis, TN

Allanson Ignition Transformers —
2721, 2275 Electronic Ignitor, 421 & 1092 Series

Memphis Control Center stocks Allanson ferromagnetic and electronic ignition transformers for oil burners and gas burners — the 2721-628G for Beckett A/AF/AFG, 421-BT636 universal 6-position replacement, 2275 electronic ignitor series, 1092 gas burner series for North American, Ray, Cleaver Brooks, Power Flame, Webster, and Gordon-Piatt, and burner-specific 421 series. Cross-reference help available — call us with your burner make and model. Free same-day shipping from Memphis, TN since 1967.

Authorized Allanson Stocking Distributor Ferromagnetic & Electronic Ignitor Series Oil & Gas Burner Transformers Free Same-Day Shipping
Leading the Way Since 1927Allanson International — industry standard ignition transformer for oil and gas burner OEMs, based in Markham, Ontario
Every Major Burner BrandBeckett, Wayne, Carlin, Gordon-Piatt, Cleaver Brooks, Power Flame, Webster, North American, and more
Ferromagnetic & Electronic Ignitor2721 conventional and 2275 electronic ignitor series — both oil and gas burner applications
Same-Day ShippingOrders by 2 PM CT ship same day — always free

Most Requested Allanson Models

The Allanson models below are the most commonly purchased across the HVAC and combustion industry. Not sure which model you need? Contact our team or call (901) 458-2000 — we cross-reference against France, Webster, Dongan, Sid Harvey, and Carlin part numbers.

Beckett A / AF / AFG 2721-628G

Ferromagnetic Ignition Transformer for Beckett A, AF, and AFG oil burners. 120V primary / 10,000V secondary, 23 mA, 60 Hz, mid-point ground. High-temperature wire construction with superior EMI/RFI shielding. Replacement gasket included ("G" suffix). Replaces obsolete 2721-628A. Not compatible with Beckett NX burners. Cross-references: France 5LAY-04, Webster T-92, Dongan XD-BK103, Sid Harvey T-92.

120V · 60Hz 10,000V Secondary 23 mA Mid-Point Ground Beckett A / AF / AFG Gasket Included
Universal Replacement 421-BT636

Universal 6-Position Replacement Ignition Transformer. 120V primary / 10,000V secondary, 23 mA, 60 Hz, mid-point ground. Six-position mounting adaptability with complete mounting hardware. Used when an original burner-specific transformer is unavailable. Cross-references: France LAUV, Webster 312-25AX0600, Dongan LJH-90, Sid Harvey T1-15. The 444-BT636 is the 240V primary equivalent.

120V · 60Hz 10,000V Secondary 23 mA Mid-Point Ground 6-Position Adaptability Large Can Series
Electronic Ignitor 2275-658

Electronic Ignitor for Beckett AFII oil burners. Allanson classifies the 2275 series as "Electronic Ignitors" — they use electronic circuitry to generate a higher-frequency, higher-voltage output compared to conventional ferromagnetic transformers. 120V / 50-60Hz, 17,500V secondary, 45mA, mid-point ground. High-voltage cables with 1/4" push-on terminals. Side bracket mounting. History of excellent operation under brownout conditions. CSA and UL listed.

120V · 50/60Hz 17,500V Secondary 45 mA · Mid-Point Gnd Beckett AFII Side Bracket Mount Electronic Ignitor
120V / 17,500V 45 mA · Mid-Point Gnd Electronic Ignitor Beckett Oil Burner 2275 Series
Gas Burner · 6,000V 1092-NA

Gas Burner Ignition Transformer — North American Burners. 120V / 6,000V. The 1092 series is Allanson's primary line for commercial gas burner ignition. The 1092-NA is for North American burner applications — other 1092 variants cover Ray Burner (1092-N), Cleaver Brooks (1092-H), Power Flame (1092-PF-G), Webster (1092-SG), and Gordon-Piatt (1092-S). All 1092 series: 120V primary / 6,000V secondary.

120V / 6,000V Gas Burner North American 1092 Series

Allanson Product Series

Allanson's catalog is organized into distinct series — each targeting a specific transformer type or application. Find your series below, then use the burner cross-reference table to find the exact model.

2721 Series — Ferromagnetic Oil Burner

Conventional ferromagnetic ignition transformers for oil burners. 120V primary / 10,000V secondary. Burner-specific models for Beckett, Wayne, Carlin, and others. The most widely stocked Allanson series in the industry.

2275 Series — Electronic Ignitors

Allanson electronic ignitors. 120V / 17,500V, 45mA, mid-point ground — higher output voltage than conventional ferromagnetic transformers. The 2275-658 is for the Beckett AFII burner. Other 2275 variants cover Wayne and Carlin applications. Contact us for models not listed online.

2275-658 2275-628G 2275-620 2275-630 2275-619

Grey = additional models available — contact us

421 Series — Oil Burner Specific & Universal

Ferromagnetic ignition transformers in the 421 series — includes burner-specific models for Gordon-Piatt, Cleaver Brooks, Power Flame, and Webster, plus the 421-BT636 universal 6-position replacement. 120V / 10,000V.

1092 Series — Gas Burner 6,000V

Gas burner ignition transformers. 120V / 6,000V. Burner-specific variants for North American, Ray Burner, Cleaver Brooks, Power Flame, Webster, and Gordon-Piatt. The 1092-F is the universal replacement version with BX connector.

Allanson Transformer — Burner Cross-Reference

Find the Allanson transformer for your burner. Also shows France, Webster, Dongan, and Sid Harvey cross-reference numbers. Can't find yours? Contact us or call (901) 458-2000.

Burner / ApplicationAllansonVoltageFranceDongan / Sid HarveyShop
Beckett A, AF, AFG2721-628G120V/10kV · 23mA · 250VA5LAY-04XD-BK103 / T-92Shop
Beckett A, AF, AFG (240V)2744-628G240V/10kV · 23mA · 250VAShop
Beckett AFII (electronic ignitor)2275-658120V/17.5kV · 45mAShop
Wayne E Oil Burner2721-620120V/10kV5LAY-30XD-WN208 / T-88Shop
Wayne Hi-Speed M/MH2721-619120V/10kVShop
Wayne Blue Angel / Eagle One2721-647120V/10kVShop
Carlin 99, 100, 101, Card Miser2721-630120V/10kVShop
Gordon-Piatt (oil, 10kV)421-661120V/10kVShop
Cleaver Brooks (oil, 10kV)421-659120V/10kVShop
Power Flame (oil, 10kV)421-655-G120V/10kVShop
Webster Engineering (oil, 10kV)421-664120V/10kVShop
Universal (oil, 120V)421-BT636120V/10kV · 23mA · 250VALAUVLJH-90 / T1-15Shop
Universal (oil, 240V)444-BT636240V/10kV · 250VAShop
North American (gas, 6kV)1092-NA120V/6kVShop
Ray Burner (gas, 6kV)1092-N120V/6kVShop
Cleaver Brooks (gas, 6kV)1092-H120V/6kVShop
Power Flame (gas, 6kV, grounded)1092-PF-G120V/6kV · w/groundShop
Webster (gas, 6kV)1092-SG120V/6kV · 3-wire primaryShop
Gordon-Piatt (gas, 6kV)1092-S120V/6kVShop
Universal (gas, BX connector)1092-F120V/6kV · BX connectorShop
Wayne E (120V, slate base)2721-637120V/10kV · 250VA5LAY-30Shop
Allanson Transformers

Allanson Transformers

Compare

Can't find your Allanson model or need a cross-reference?

Give us your burner make, model, and existing transformer number — we'll find the right replacement.

Allanson Transformers — Frequently Asked Questions

Common questions about Allanson ignition transformers. Contact our team or call (901) 458-2000 for cross-reference and specification help.

What is the difference between Allanson ferromagnetic ignition transformers and electronic ignitors?

Ferromagnetic transformers (2721 series, 421 series) use a conventional iron-core design to step 120V up to 10,000V secondary for oil burner ignition. Electronic ignitors (2275 series) use electronic circuitry to generate a higher-frequency output — 17,500V secondary at 45mA — producing a more intense spark. The 2275-658 is for the Beckett AFII burner specifically; other 2275 variants cover Wayne and Carlin applications. The ferromagnetic 2721 series covers Beckett A, AF, and AFG. These are not interchangeable — always verify your specific burner model before ordering.

What Allanson transformer replaces the 2721-628A?

The Allanson 2721-628G is the direct replacement for the obsolete 2721-628A. The "G" suffix indicates a replacement gasket is included. Specs: 120V primary, 10,000V secondary, 23mA, mid-point ground. For Beckett A, AF, and AFG oil burners. Not compatible with Beckett NX burners.

What is the difference between the Allanson 2721-628G and 2275-658?

Both are Allanson ignition transformers for Beckett oil burners but they are different product types and for different burner models. The 2721-628G is a conventional ferromagnetic transformer for Beckett A, AF, and AFG burners — 120V / 10,000V, 23mA, mid-point ground. The 2275-658 is an electronic ignitor specifically for the Beckett AFII burner — 120V / 17,500V, 45mA, mid-point ground. These are not interchangeable — the correct model depends on which specific Beckett burner model you have. Check your burner nameplate for the exact model designation.

What are the cross-reference numbers for the Allanson 2721-628G?

The Allanson 2721-628G cross-references to: France 5LAY-04, Webster T-92, Dongan XD-BK103, Sid Harvey T-92. It also replaces the obsolete Allanson 2721-628A and 2721-627. All are ferromagnetic ignition transformers for Beckett A, AF, and AFG oil burners.

What is the Allanson 421-BT636 and what does it replace?

The 421-BT636 is a universal 6-position replacement ignition transformer — 120V / 10,000V, 23mA, mid-point ground — used when the original burner-specific transformer is unavailable. Cross-references: France LAUV, Webster 312-25AX0600, Dongan LJH-90, Sid Harvey T1-15. Includes complete mounting hardware with six-position adaptability. The 444-BT636 is the 240V primary equivalent.

What is the difference between the Allanson 1092 gas burner series variants?

All 1092 series are 120V primary / 6,000V secondary gas burner ignition transformers. The variants differ by which commercial gas burner they fit: 1092-NA = North American, 1092-N = Ray Burner, 1092-H = Cleaver Brooks, 1092-PF-G = Power Flame (with ground wire), 1092-SG = Webster (3-wire primary), 1092-S = Gordon-Piatt, 1092-F = universal replacement with BX connector. All stocked at Memphis Control Center.

For emergencies, outside of business hours, call #901-604-7069