There are no products listed under this category.
Memphis Control Center stocks Resideo controls — sold under the Honeywell Home brand — for residential and commercial HVAC and hydronic heating systems. Aquastat controllers (L4006, L4008, L6006, L6008, L4081 series) for boiler high-limit, low-limit, and circulator control. Well assemblies (121371A, 121371B, 121371AA) for immersion sensing. Ignition modules (S8610U universal intermittent pilot, S87B direct spark). Pilot burners (Q345U1005, Q345A1313, Q314A4586). Hot surface igniters (Q4100C series). Thermostats (T498B1512 electric heat, T834L low-volt). AT140A1000 120V/24V transformer for HVAC low-voltage power. Family-owned, serving Memphis since 1967.
Memphis Control Center stocks Resideo controls across three categories: Aquastat controllers and well assemblies, ignition controls and pilot burners, and thermostats. Contact us or call (901) 458-2000 with your model number.
Resideo / Honeywell Home Aquastat controllers are immersion or remote-bulb temperature controllers for hydronic heating systems — boilers, storage tanks, and piping. They provide high-limit shutoff (prevents overheating), low-limit control (maintains minimum temperature for tankless coil systems), and circulator control. L4006 series — immersion type with copper bulb, 100–240°F. L4008 series — remote bulb immersion type, high or high-limit/manual reset. L6006 series — SPDT contacts for circulator + high/low limit. L6008 series — remote bulb SPDT, circulator and low-limit. L4081 — high/low limit combination.
| Model | Type | Range | Contacts | Shop |
|---|---|---|---|---|
| L4006A1967 | Immersion · hi/lo limit | 100–240°F | SPDT | Shop |
| L4006A1678 | Immersion · hi/lo limit | 100–240°F | SPST | Shop |
| L4006E1067 | Immersion · high limit · manual reset | 130–270°F | SPST | Shop |
| L6006A1145 | Immersion · hi/lo limit · circulator | 100–240°F | SPDT | Shop |
| L6006C1018 | Strap-on · hi/lo · circulator | 65–200°F | SPDT | Shop |
| L4008A1015 | Remote bulb · hi/lo limit | 100–240°F | SPST · 66" cap. | Shop |
| L4008A1130 | Remote bulb · hi/lo limit | 130–270°F | SPST · 10' cap. | Shop |
| L4008E1040 | Remote bulb · high limit · manual reset | 130–270°F | SPST · 66" cap. | Shop |
| L4008E1156 | Remote bulb · high limit · manual reset | 130–270°F | SPST · 66" cap. | Shop |
| L4008E1305 | Remote bulb · high limit · manual reset | 100–240°F | SPST · 66" cap. | Shop |
| L6008A1192 | Remote bulb · hi/lo · circulator | 100–240°F | SPDT · 66" cap. | Shop |
| L4081A1023 | Immersion · hi/lo combination | 110–240°F | SPST | Shop |
Resideo / Honeywell Home well assemblies are copper immersion wells that thread into a boiler or pipe tapping and accept the Aquastat sensing bulb. Required when the boiler or system pipe does not have a direct immersion tapping — the well creates the tapping and protects the bulb from direct fluid contact. 121371A — 1/2" NPT, 3" insertion, copper. 121371B — 3/4" NPT, 3" insertion, 1-1/2" insulation depth, copper. 121371AA — well clamp assembly with clamp capillary for strap-on surface mounting (for use with L6006C and similar strap-on Aquastats).
| Model | Description | NPT | Insertion | Shop |
|---|---|---|---|---|
| 121371A | Copper well assembly | 1/2" | 3" | Shop |
| 121371B | Copper well assembly · 1-1/2" insulation | 3/4" | 3" | Shop |
| 121371AA | Well clamp assembly with clamp capillary — strap-on | — | — | Shop |
Resideo / Honeywell Home ignition controls for residential and light commercial furnaces and heating appliances. The S8610U3009 is the universal intermittent pilot module — one of the most widely used ignition controls in the industry. It configures for 15- or 90-second ignition trial, with or without prepurge, single or two-rod flame sensing, compatible with natural or LP gas. Replaces over 400 White-Rogers, Robertshaw, Johnson Controls, and UTEC (HSC) intermittent pilot ignition modules. The S87B1016 is a direct spark ignition (DSI) module for gas burners. The Q345U1005 universal pilot burner replaces most standing and intermittent pilot assemblies. The Q4100C series are silicon carbide hot surface igniters.
| Model | Type | Description | Shop |
|---|---|---|---|
| S8610U3009 | Ignition module | Universal intermittent pilot · 24V · configurable trial 15 or 90 sec · NG/LP | Shop |
| S87B1016 | DSI module | Direct spark ignition · 24V · 0.8-sec flame failure · 11-sec lockout · NG/LP | Shop |
| Q345U1005 | Pilot burner | Universal intermittent pilot · adjustable tip · NG/LP · 1/4" & 1/8" compression | Shop |
| Q345A1313 | Pilot burner | Natural gas · B bracket · single tip left · BCR-18 orifice | Shop |
| Q345A1305 | Pilot burner | Natural gas · B bracket · BCR-18 orifice — replaced by Q345U1005 | Shop |
| Q314A4586 | Pilot burner | Standing pilot · NG/LP · front single tip · BCR-18 & BBR-10 orifices · B bracket | Shop |
| Q4100C9056 | Hot surface igniter | 120V · silicon carbide · 5-1/4" leads · rib offset left · 392°F · NG/LP | Shop |
| Q4100C9050 | Hot surface igniter | 120V · silicon carbide · 11" leads · rib on right · 3 brackets · NG/LP | Shop |
| AT140A1000 | Transformer | 120V input / 24V output · HVAC low-voltage power supply | Shop |
Resideo / Honeywell Home thermostats for electric heat and low-voltage HVAC systems. The T498B1512 is a line-voltage electric heat thermostat for electric baseboard, convector, and fan-forced heaters — DPST, 22A at 120/208/240V and 19A at 277V, bimetal sensor, 40–80°F range, vertical mount, brush gold finish, includes locking cover. The T834L1004 is a low-voltage mercury-free thermostat for single-stage cool systems.
| Model | Type | Description | Shop |
|---|---|---|---|
| T498B1512 | Line voltage | Electric heat thermostat · DPST · 22A · 120/208/240/277V · 40–80°F · bimetal · vertical | Shop |
| T834L1004 | Low voltage | Mercury-free thermostat · single-stage cool · low voltage | Shop |
Common questions from HVAC technicians, plumbing and heating contractors, and boiler service professionals about Resideo Aquastats, ignition controls, and pilot burners. Contact us or call (901) 458-2000 with your model number.
What is the difference between Resideo and Honeywell?
Resideo Technologies, Inc. was spun off from Honeywell International as an independent publicly traded company (NYSE: REZI) on October 29, 2018. Resideo manufactures and sells the same heating, cooling, and home comfort controls under a long-term exclusive license of the Honeywell Home brand. The controls — Aquastats, ignition modules, pilot burners, thermostats — are the same products as the former Honeywell Home and Heating lines, now made and sold by Resideo. Part numbers remain the same. You may see "Resideo," "Honeywell Home," or both on the packaging — they are the same company and same product.
What does an Aquastat controller do?
An Aquastat is an immersion or remote-bulb temperature controller for hydronic heating systems. It monitors boiler water temperature and controls the burner and/or circulator based on setpoints. High-limit function: shuts off the burner if water temperature exceeds a safe maximum — prevents overheating and boiler damage. Low-limit function: keeps boiler water at a minimum temperature for tankless domestic hot water coils — the boiler fires to maintain temperature even when there's no heating call. Circulator control: SPDT contacts on L6006/L6008 models start and stop the circulator pump based on temperature. Resideo's L4006, L4008, L6006, and L6008 series cover all of these functions in various configurations.
What is the difference between the L4006, L4008, L6006, and L6008 Aquastats?
L4006 series: immersion type with 3/8" × 2-7/8" copper bulb, mounts directly in a boiler tapping. SPST (L4006A1678) or SPDT (L4006A1967) contacts. L4008 series: remote bulb — the sensing bulb is at the end of a capillary that extends away from the control body, used when direct mounting isn't possible. L6006 series: SPDT contacts designed for combined circulator control and high/low limit. L6008 series: remote bulb version of the L6006 with SPDT contacts. In short: L4006/L4008 are high or low limit; L6006/L6008 add dedicated circulator control. L4006/L6006 are immersion (direct mount); L4008/L6008 are remote bulb (capillary).
What does the S8610U3009 universal intermittent pilot module do?
The S8610U3009 is a universal intermittent pilot ignition control module for gas furnaces and heating appliances. It controls the ignition sequence: sparks the pilot, proves the pilot flame via flame sensing rod, then opens the main gas valve. If the pilot doesn't light within the trial period, it locks out. The S8610U3009 is configurable for 15-second or 90-second ignition trial, with or without 30-second prepurge, single or two-rod flame sensing, compatible with natural or LP gas. It replaces a wide range of older Honeywell S86 and S8610 series modules and is one of the most widely stocked ignition controls in the industry.
What is the difference between Q345A1305, Q345A1313, and Q345U1005 pilot burners?
Q345A1305: natural gas only, B bracket, BCR-18 orifice — replaced by Q345U1005 (still available while supply lasts). Q345A1313: natural gas only, B bracket, BCR-18 orifice, tip directed left — still active. Q345U1005: universal replacement compatible with NG and LP gas, adjustable tip, 1/4" and 1/8" compression fittings, U-style bracket. The Q345U1005 is the current recommended replacement for most Q345 series pilots. Call (901) 458-2000 with your old pilot part number and we'll confirm the correct replacement.
How do I select the right Aquastat well assembly?
Select by NPT thread size and mounting type. 121371A: 1/2" NPT, 3" insertion, copper — for boiler tappings with 1/2" pipe thread. 121371B: 3/4" NPT, 3" insertion, 1-1/2" insulation depth, copper — for 3/4" tappings common on larger boilers. 121371AA: well clamp assembly for strap-on surface mounting — used with L6006C and similar strap-on Aquastats that don't require a pipe tapping. No tapping available on the boiler? Use the 121371AA strap-on clamp. Have a pipe tapping? Match the NPT size (1/2" → 121371A, 3/4" → 121371B).
Call us with your model number — Aquastat, ignition module, pilot burner, or thermostat. We'll confirm availability and same-day shipping from Memphis, TN.
For emergencies, outside of business hours, call #901-604-7069