Flame Safety Controls Since 1953

Protection Controls Inc. Flame Safeguard Controls & UV Scanners

Genuine Protectofier combustion safeguards, PC-II ultraviolet scanners, Flame-Pak amplifiers, and Timofier plug-in timers for boilers, furnaces, and industrial burner systems. Stocked and shipped from Memphis, TN.

Genuine OEM Parts UL, FM & CSA Approved Same-Day Shipping Available Expert Technical Support
UL, FM & CSA Listed
Every Protectofier system carries third-party safety approvals required by NFPA combustion codes.
4-Second Flame Response
Protectofier cuts fuel within 4 seconds of flame loss, meeting the tightest flame-failure response requirements.
Plug-In Modular Design
Flame-Pak amplifiers, relays, and Timofiers are plug-in modules — swap components without rewiring the panel.
Expert Technical Support
Our team can help you identify the correct Protectofier form, Timofier timing, and scanner type for your application.

Protection Controls Product Lines

Protection Controls Inc. has manufactured flame safety equipment for boilers, furnaces, and industrial burners since 1953. The company is credited with developing the rectifying principle for flame safety control — where the flame itself conducts DC current to signal presence — a method still used across the industry today. All systems carry UL, FM, and CSA approval and are designed to meet NFPA combustion safety standards.

Combustion Safeguard
Protectofier — Form 6642V Series
Single & multi-burner flame safeguard controls
Solid-state combustion safeguard for gas or oil burners. Modular plug-in design — accepts Flame-Pak amplifiers, Timofier timers, and interchangeable relays. Cuts fuel within 4 seconds of flame loss. 120V, 50/60 Hz. UL, FM, CSA listed.
Combustion Safeguard
Protectofier — Form 7761 Series
Single-burner with integrated purge timer
Compact single-burner safeguard with built-in purge timer. Suitable for automatically lit burner applications that require timed pre-purge before ignition trial. Lock-out model available.
UV Flame Scanner
PC-II Ultraviolet Scanner
UV flame detection for gas & oil burners
UV-sensitive scanner for use exclusively with the Protectofier combustion safeguard. Detects ultraviolet radiation from gas or oil flames. Encapsulated sensor tube, gas-tight housing. Operating range: -20°F to 212°F. Peak spectral response: 210 nm. 2-wire connection. Mountable in any position.
Amplifier Module
Flame-Pak (SS100A)
Plug-in solid-state flame detection amplifier
The core flame-sensing amplifier module of the Protectofier system. Solid-state design. Accepts signal from flame rod (rectification), PC-II UV scanner, or both simultaneously. Plug-in replacement — no rewiring required.
Timer Module
Timofier Plug-In Timer
Fixed-time pre-purge & ignition trial modules
Plug-in fixed-time modules that set pre-purge duration and ignition trial period for the Protectofier. Non-adjustable — timing is specified at ordering (e.g., 15-sec purge / 15-sec ignition, 3-min purge, 5-min purge). Ensures code-compliant purge cycles on automatically lit burners.
Accessories
Scanner Accessories
Lenses, insulators & test tools
Quartz lenses (standard and magnifying), heat seal assemblies, fiber insulators, insulating/purging nipples, and flame simulators for commissioning and testing Protectofier systems.

Protection Controls Parts We Stock

Memphis Control Center stocks genuine Protection Controls parts for fast ship-out. If you need a Protectofier form or Timofier timing not listed below, call us — we can source it.

Part Number Description Category
SS100A Flame-Pak Solid-State Amplifier Module Flame-Pak Amplifier
PC-II PC-II Ultraviolet Scanner — Straight, Standard Connector UV Scanner
ACF ACF Plug-In Relay (Non-Recycle / Lock-Out) Relay Module
R-C100 R-C100 Control Unit Control
FLAME-SIMULATOR Flame Simulator — Test & Commissioning Tool Test Accessory
MAGNIFYING QUARTZ LENS Magnifying Quartz Lens for PC-II Scanner Scanner Accessory
Fiber insulator Fiber Insulator for PC-II Scanner Mounting Scanner Accessory

How the Protectofier System Works

The Protectofier is a modular, solid-state combustion safeguard that continuously monitors burner flame and cuts fuel automatically within 4 seconds if flame is lost. Understanding the system components helps you order the right parts.

Flame Detection — Two Methods
The Protectofier can use a flame rod, a PC-II UV scanner, or both on the same system simultaneously. With a flame rod, the flame acts as a rectifier — it converts AC to DC, and the Flame-Pak detects that DC signal. With the PC-II scanner, UV radiation from the flame drives a UV-sensitive tube that creates the signal. Both methods connect to the same Flame-Pak amplifier slot.
Flame Rod (Rectification) PC-II UV Scanner Dual-Sensing Capable Gas & Oil Compatible
Modular Plug-In Components
The Protectofier is built around interchangeable plug-in modules. The Flame-Pak amplifier, relay, power transformer (SS3CP), and Timofier timer all plug into the base unit. Field replacement requires no rewiring. This makes it possible to swap a faulty Flame-Pak or change Timofier timing without replacing the entire control panel.
Flame-Pak Amplifier (SS100A) Timofier Timer ACF Lock-Out Relay SS3CP Transformer
Timofier — Purge & Ignition Timing
The Timofier is a plug-in, non-adjustable timer that controls pre-purge duration and ignition trial period. Timing is fixed at the factory to the specification you order — common configurations include 15-second purge / 15-second ignition (M15-15J), 3-minute purge (M178-02), and 5-minute purge (M298-02). Ensures code-compliant purge cycles without field adjustment. Replace a Timofier by ordering the correct timing version for your application.
15 sec / 15 sec Purge/Ignition 3-Minute Purge 5-Minute Purge Non-Adjustable Fixed Timing
Multi-Burner Systems — TELEFIER Fault Identification
Multi-burner Protectofier models include the TELEFIER — a fault indicator light that pinpoints which burner caused a system shutdown. This eliminates the need to inspect each burner individually after a trip and speeds up recommissioning on multi-burner boilers and industrial ovens.
Per-Burner Fault Indication Single-Burner Models Available Up to 6-Burner Configurations

Ordering the Right Protectofier Form

Protectofier form numbers encode the system configuration. The key variables are the number of burners supervised, whether a Timofier timer is included, whether the model re-lights after flame failure (or locks out), and whether proof-of-closure interlock is required. Contact us with your existing control's form number and we can help confirm the correct replacement.

Suffix / Option What It Means
V Standard Protectofier base (6642V series)
B Lock-out (burner locks out after flame failure — requires manual reset)
NR Non-recycle (does not attempt re-light after flame failure)
T Includes Timofier plug-in purge/ignition timer
VT Proof-of-closure interlock — valve must prove closed before purge starts
M-xxx Timofier model number specifying purge and ignition timing (e.g., M165-15 = 165-sec purge, 15-sec ignition)
7761 Series Compact single-burner model with integrated timer; form 7761-4 includes 4-minute timer
About Protection Controls Inc. — Founded in 1953 by Robert Yates, Protection Controls Inc. developed the rectifying principle for flame safety control, in which the burner flame itself conducts DC current to signal flame presence. This method remains a standard in the industry. The company has participated in drafting NFPA combustion safety standards and has been an IHEA member since its founding. All Protectofier systems are approved by UL, FM, and CSA. The Yates family continues to own and operate the company. Memphis Control Center stocks genuine Protection Controls parts for fast turnaround on boiler room flame safety repairs.

Protection Controls

(Showing 7 of 7)

Protection Controls: Advanced Flame Safety Solutions

Compare
Need help finding the right Protectofier part or form? Have your existing control's form number ready — we'll confirm the correct replacement or component.

Frequently Asked Questions — Protection Controls

Common questions about Protectofier flame safeguard controls, PC-II UV scanners, Timofier timers, and ordering the right form for your application.

The Protectofier is a solid-state combustion safeguard made by Protection Controls Inc. It continuously monitors one or more burners for flame presence and cuts the fuel supply within 4 seconds if flame is lost. This prevents dangerous fuel buildup that could result in an explosion or fire. The Protectofier is used on boilers, furnaces, ovens, and other industrial heating equipment burning gas or oil. All models carry UL, FM, and CSA approval and are designed to comply with NFPA combustion safety standards.

Both are Protectofier combustion safeguards, but they target different applications. The 6642V series is the modular, full-featured platform that accepts plug-in Flame-Pak amplifiers, Timofier timer modules, interchangeable relays, and supports single or multi-burner configurations. It is the most common Protectofier form in commercial and industrial boiler rooms. The 7761 series is a compact single-burner control with an integrated purge timer built in, suited for simpler automatically lit burner applications. If your system uses plug-in Timofier modules or supervises multiple burners, you need the 6642V platform.

The Timofier is a plug-in, fixed-time module that controls pre-purge duration and ignition trial timing for the Protectofier. It ensures the combustion chamber is purged of residual fuel before each ignition attempt, as required by NFPA combustion codes on automatically lit burners. The timing is non-adjustable and fixed at the factory, so you order the timing you need. Common configurations include M15-15J (15-sec purge / 15-sec ignition), M178-02 (3-minute purge), and M298-02 (5-minute purge). The model number on your existing Timofier is the easiest way to reorder the correct replacement.

The PC-II is an ultraviolet flame scanner made exclusively for use with the Protectofier combustion safeguard. It detects UV radiation emitted by gas or oil flames and sends a signal to the Flame-Pak amplifier inside the Protectofier. You need a PC-II when your Protectofier is configured for UV flame sensing rather than, or in addition to, flame rod sensing. The PC-II mounts in any position, operates from -20°F to 212°F, and connects via a 2-wire cable. Protection Controls recommends replacement approximately every 8,000 hours of operation, or sooner in high-temperature environments.

The ACF is a plug-in lock-out relay that prevents the Protectofier from attempting to re-light the burner after a flame failure shutdown. Once the ACF latches out after a flame failure, a manual reset is required before the system will allow another ignition attempt. On NR (non-recycle) Protectofier models, the ACF is included. Many NFPA codes and equipment manufacturers require non-recycle operation on larger commercial and industrial burners.

Memphis Control Center primarily stocks replacement and service components for existing Protectofier systems, including Flame-Pak amplifiers (SS100A), PC-II UV scanners, ACF relays, Timofier timing modules, quartz lenses, fiber insulators, and flame simulators. For complete Protectofier panel assemblies, availability varies by form and configuration. Call us at (901) 458-2000 with your existing control's form number and we can confirm availability, lead time, and whether a component replacement may be the faster solution.

For emergencies, outside of business hours, call #901-604-7069