Description
The Dongan A06-SA6 Ignition Transformer is designed for reliable ignition in commercial and industrial gas and oil burner applications. Built with a 120V primary input and 6000V secondary output, this ignition transformer delivers the high-voltage spark needed for dependable burner startup.
The A06-SA6 features a durable enclosed design, 60 Hz operation, 175 VA rating, and an end-grounded secondary, making it a trusted replacement option for burner and boiler ignition systems. It is commonly used in industrial combustion equipment, heating systems, ovens, process burners, and related flame ignition applications.
Memphis Control Center supplies burner controls, ignition components, flame safety parts, and boiler control replacement parts for commercial and industrial facilities.
Dongan A06-SA6 Ignition Transformer | 120V Primary, 6000V Secondary, 175VA, 100% Duty Cycle, End Grounded. A06SA6 AO6SA6
The Dongan A06-SA6 ignition transformer is a heavy-duty, enclosed transformer designed for oil and gas burner ignition systems. With a robust 120V primary input and a 6000V secondary output, it delivers consistent, high-voltage performance for reliable ignition. Built for demanding environments, this unit offers a 100% duty cycle, durable end-grounded construction, and a compact footprint.
Key Features
-
Reliable Performance – High-voltage 6000 VAC secondary for consistent spark ignition
-
Rugged Design – Fully enclosed and end-grounded for enhanced durability in harsh environments
-
100% Duty Cycle – Engineered for continuous operation without overheating
-
Compact Size – Easy to mount in tight burner compartments
-
OEM-Grade Build – Ideal for oil and gas burner ignition systems
Specifications
| Attribute | Value |
|---|---|
| Manufacturer | Dongan Electric Mfg. Co. |
| Model Number | A06-SA6 |
| Type | Ignition Transformer (Enclosed) |
| Primary Voltage | 120 VAC |
| Secondary Voltage | 6000 VAC |
| Power Rating | 175 VA |
| Frequency | 60 Hz |
| Phase | Single Phase |
| Duty Cycle | 100% |
| Dimensions (L x W x H) | 4.44" x 6.75" x 4.31" |
| Weight | 8.9 lbs |
| Grounding | End Grounded |
| Application | Oil & Gas Burner Ignition Systems |
Applications
The A06-SA6 transformer is engineered for industrial and commercial oil or gas burner systems requiring high-voltage ignition. It is commonly used in boilers, furnaces, and combustion equipment where a stable and long-lasting spark is essential.
FAQ
What is the Dongan A06-SA6 used for?
The Dongan A06-SA6 is used to provide high-voltage ignition for gas and oil burner systems.
What is the voltage rating of the A06-SA6?
The A06-SA6 has a 120V primary input and 6000V secondary output.
Is the A06-SA6 used for boiler and burner systems?
Yes, it is commonly used in commercial and industrial burner, boiler, and combustion applications.