Same Day Shipping On In Stock Products Ordered Before 2:00pm CT                                                                                                                                                                                                 8:00am - 5:00pm CT | Monday - Friday  

SIGN IN FOR BEST PRICING                                 

RM7800L1053 Microprocessor-Based Burner Control with Proven Purge, LHL-LF & HF Sequencing, Intermittent Pilot Valve, and Integrated S7800A1142 Keyboard Display — 120 Vac

Honeywell

SKU:
RM7800L1053
$3,756.73
$3,756.73

Description

RM7800L1053 Burner Control
Programming Control with Proven Purge, LHL-LF & HF Sequences, Intermittent Pilot Valve, Includes Keyboard Display, 120 Vac

The RM7800L1053 is a microprocessor-based integrated burner control designed for automatically fired gas, oil, coal, or combination fuel single burner applications. It includes a proven purge feature and supports LHL (Low-High-Low), LF (Low Fire), and HF (High Fire) sequencing. This model features an intermittent pilot valve and comes equipped with a Honeywell S7800A1142 Keyboard Display Module for setup, diagnostics, and fault monitoring.

Key Features

  • Built-in Keyboard Display Module (S7800A1142) for real-time diagnostics, setup, and fault annunciation

  • Provides automatic burner sequencing, flame supervision, lockout status, and system diagnostics

  • Compatible with all 7800 Series plug-in flame amplifiers (UV, IR, rectification)

  • Five function Run/Test switch enables local servicing and commissioning

  • Five LEDs provide sequence status, including a blinking Power LED for lockout code display

  • Nonvolatile memory retains history files and lockout events after power loss

  • Access terminals for external electrical checks and voltage testing

  • Application flexibility with selectable Airflow Switch check and pilot options

  • Supports communication modules and interface options for remote monitoring

  • Compact design mounts directly to standard Honeywell Q7800A or Q7800B universal subbases

Technical Specifications

Specification Value
Application Programming Control
Voltage 120 Vac
Pilot Type Interrupted
Second Stage Pilot Valve Intermittent
Flame Establishing Time – Pilot 4 sec or 10 sec
Flame Establishing Time – Main 10 sec or Intermittent
Interlocks Lockout
Preignition Yes
Airflow Check User Selectable
Display S7800A1142 Keyboard Display Included
Compatible Amplifiers R7847, R7848, R7849, etc.
Flame Detection UV, IR, Rectification (via amplifier)
Memory Nonvolatile

Common Applications

  • Industrial burners requiring full sequencing and proven purge capability

  • Systems requiring selectable flame establishing times and flexible interlock logic

  • Installations needing built-in diagnostics and lockout fault history

  • Multi-stage burner systems with intermittent pilot control

  • Retrofit and upgrade projects needing a plug-and-play Honeywell 7800 Series solution

Extra Information

Brand:
Honeywell
Weight:
3.10 LBS

For emergencies, outside of business hours, call #901-604-7069